Dell 3 Computer Hardware User Manual


 
206 Troubleshooting
www.dell.com | support.dell.com
Configuration
of NVRAM and
drives
mismatch. Run
View/Add
Configuration
option of PERC
3 BIOS
Configuration
Utility.
Press any key
to run the
Configuration
Utility.
The configuration
stored in the PERC 3
adapter does not
match the
configuration stored in
the drives.
Press <Ctrl><M> to run
the BIOS Configuration
Utility. Choose Configure
>
View/Add Configuration
to examine both the
configuration in non-volatile
random access memory
(NVRAM) and the
configuration stored on the
hard drives. Resolve the
problem by selecting one of
the configurations.
Unresolved
configuration
mismatch
between disks
and NVRAM on
the adapter
after creating
a new
configuration
Some legacy
configurations in the
drives cannot be
cleared.
Clear the configuration.
Low-level format the related
drives and re-create the
configuration.
1 Logical Drive
Failed
A logical drive failed
to sign on.
Make sure all physical drives
are properly connected and
are powered on. Run the
BIOS Configuration Utility
to find out if any physical
drives are not responding.
Reconnect, replace, or
rebuild any drive that is not
responding.
TBBU Cache-data
seems to be
INVALID for
current
adapter.
The data on the
transportable battery
backup (TBBU) unit is
not valid for the
current controller.
Power off and put the TBBU
on the proper adapter. Or if
you want to discard the
Cache-data and proceed,
press Y:.
Table 13-2. BIOS Boot Error Messages
(continued)
Message Problem Suggested Solution