Dell 3 Computer Hardware User Manual


 
208 Troubleshooting
www.dell.com | support.dell.com
Other BIOS Error Messages
Table 13-3 explains the other BIOS error messages that can display.
Table 13-3. Other BIOS Error Messages
Message Problem Suggested Solution
Following
SCSI disk not
found and no
empty slot
available for
mapping it
The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No
slot is available to map the
physical drive. PERC 3
cannot resolve the
physical drives into the
current configuration.
Reconfigure the array.
Following
SCSI IDs have
the same data
y, z
Channel x: a,
b, c
The physical drive
roaming feature found the
same data on two or more
physical drives on channel
x with SCSI IDs a, b, and
c. PERC 3 cannot
determine the drive that
has the duplicate
information.
Remove the drive or drives
that should not be used.
Unresolved
configuration
mismatch
between disks
and NVRAM on
the adapter
The PERC 3 is unable to
determine the proper
configuration after
reading both NVRAM and
Configuration on Disk.
Press <Ctrl><M> to run
the BIOS Configuration
Utility. Choose
Configure
> New
Configuration to create a
new configuration.
CAUTION: This will delete
any existing configuration.