Dell 3 Computer Hardware User Manual


 
Troubleshooting 207
X Logical
Drives Degraded
x number of logical
drives signed on in a
degraded state.
Make sure all physical drives
are properly connected and
are powered on. Run the
BIOS Configuration Utility
to find whether any physical
drives are not responding.
Reconnect, replace, or
rebuild a drive that is not
responding.
1 Logical Drive
Degraded
A logical drive signed
on in a degraded state.
Make sure all physical drives
are properly connected and
are powered on. Run the
BIOS Configuration
Manager to find out if any
physical drives are not
responding. Reconnect,
replace, or rebuild any drive
that is not responding.
Insufficient
memory to run
BIOS. Press any
key to
continue…
Not enough PERC 3
memory to run PERC
3 BIOS.
Make sure PERC 3 cache
memory has been properly
installed.
Insufficient
Memory
Not enough memory
on the PERC 3
adapter to support the
current configuration.
Make sure PERC 3 cache
memory has been properly
installed.
The following
SCSI IDs are
not responding:
Channel x:a.b.c
The physical drives
with SCSIO IDs a, b,
and c are not
responding on SCSI
channel x.
Make sure the physical drives
are properly connected and
are powered on.
Table 13-2. BIOS Boot Error Messages
(continued)
Message Problem Suggested Solution