Chapter 39 Compare API | PCI-DMC-A01 / PCI-DMC-B01
39-12 Revised March, 2012
Custom mode
When set to custom mode, level table's value is set to 0x88880000 as shown in Fig. 39.2.
Figure 39.2 Compare Output's custom mode
※ In custom mode, Trigger On's position table is set
using the “level_table” parameter in
API”_DMC_01_channel1_position_compare_table_level”.
※ Trigger time is the time required to reach the next position (ex. time taken to move from
position 1000 to position 2000)
Example
U16 CardNo = 0;
U16 Mode = 1;
I16 status = _DMC_01_channel1_output_mode (CardNo, mode);