RPS Installation
Follow the instructions below to connect an RPS power supply to the Switch (DPS-200 to DES-3828/DES-3852 or DPS-600 to
DES-3828P). The DPS-200 is a redundant power-supply unit designed to conform to the voltage requirements of the switches
being supported. DPS-200 can be installed into DPS-900, or DPS-800.
DPS-900
The DPS-900 is a standard-size rack mount (5 standard units in height) designed to hold up to eight DPS-200 redundant power
supplies.
Figure 2 - 6. Installing the DPS-200 into the DPS-900
The RPS can be mounted in a standard 19" rack. Use the following diagram to guide you.
Figure 2 - 7. Installing the DPS-900 into the equipment rack
CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the
rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, always
install the stabilizers before installing components in the rack. After installing components in a rack, do
not pull more than one component out of the rack on its slide assemblies at one time. The weight of
more than one extended component could cause the rack to tip over and may result in injury.
CAUTION: The AC power cord for the Switch should be disconnected before proceeding
with installation of the DPS-200.