D-Link DES-3800 Series Switch User Manual


 
xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch
307
Figure 12- 14. Tx Error Analysis window (table)
The following fields may be set or viewed:
Parameter Description
Time Interval
Select the desired setting between 1s and 60s, where "s" stands for seconds. The default
value is one second.
Record Number
Select number of times the Switch will be polled between 20 and 200. The default value is 20.
ExDefer
Counts the number of packets for which the first transmission attempt on a particular interface
was delayed because the medium was busy.
LateColl
Counts the number of times that a collision is detected later than 512 bit-times into the
transmission of a packet.
ExColl
Excessive Collisions. The number of packets for which transmission failed due to excessive
collisions.
SingColl
Single Collision Frames. The number of successfully transmitted packets for which
transmission is inhibited by more than one collision.
Coll
An estimate of the total number of collisions on this network segment.
Show/Hide
Check whether or not to display ExDefer, LateColl, ExColl, SingColl, and Coll errors.
Clear
Clicking this button clears all statistics counters on this window.
View Table Clicking this button instructs the Switch to display a table rather than a line graph.