94 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
Note – The server takes about one minute to power off. The ILOM console does not
indicate when the system is actually powered off.
c. Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output is a
sign that POST did not detect any faults:
Note – Depending on the configuration of ILOM POST variables and whether POST
detected faults or not, the system might boot, or the system might remain at the ok
prompt. If the system is at the ok prompt, type boot.
d. Return the virtual keyswitch to Normal mode.
Related Information
■ “Remove FB-DIMMs” on page 85
■ “Install Replacement FB-DIMMs” on page 87
■ “Verify Successful Replacement of Faulty FB-DIMMs” on page 89
■ “FB-DIMM Configuration Guidelines” on page 95
-> start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS
-> start /SYS/console
.
.
.
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
-> set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’