Fujitsu T5220 Server User Manual


 
Servicing Motherboard Components 107
SPARC Enterprise T5220: PCIe filler panels are located on the riser board
assembly. Press the filler panel into the riser board back panel from the rear.
Caution To ensure proper system cooling and EMI shielding, you must use the
appropriate PCIe filler panel for the server.
Related Information
“Install a PCIe or XAUI Card” on page 107
“Remove a PCIe/XAUI Riser” on page 102
“Install a PCIe/XAUI Riser” on page 104
Install a PCIe or XAUI Card
1. Unpack the replacement PCIe or XAUI card and place it on an antistatic mat.
2. Locate the proper PCIe/XAUI slot for the card you are replacing.
3. If necessary, review the PCIe and XAUI card guidelines to plan your
installation.
See “PCIe/XAUI Card Configuration Reference for SPARC Enterprise T5120
Servers” on page 110 for additional information.
4. Remove the PCIe/XAUI riser board.
See “Remove a PCIe/XAUI Riser” on page 102.
5. Remove the PCI filler panel.
SPARC Enterprise T5120 servers: PCIe filler panels are located in the
removable PCI cross beam. Press the filler panel in from the rear until it snaps
into place, as shown in the following figure.