Servicing Motherboard Components 107
■ SPARC Enterprise T5220: PCIe filler panels are located on the riser board
assembly. Press the filler panel into the riser board back panel from the rear.
Caution – To ensure proper system cooling and EMI shielding, you must use the
appropriate PCIe filler panel for the server.
Related Information
■ “Install a PCIe or XAUI Card” on page 107
■ “Remove a PCIe/XAUI Riser” on page 102
■ “Install a PCIe/XAUI Riser” on page 104
▼ Install a PCIe or XAUI Card
1. Unpack the replacement PCIe or XAUI card and place it on an antistatic mat.
2. Locate the proper PCIe/XAUI slot for the card you are replacing.
3. If necessary, review the PCIe and XAUI card guidelines to plan your
installation.
See “PCIe/XAUI Card Configuration Reference for SPARC Enterprise T5120
Servers” on page 110 for additional information.
4. Remove the PCIe/XAUI riser board.
See “Remove a PCIe/XAUI Riser” on page 102.
5. Remove the PCI filler panel.
■ SPARC Enterprise T5120 servers: PCIe filler panels are located in the
removable PCI cross beam. Press the filler panel in from the rear until it snaps
into place, as shown in the following figure.