Fujitsu T5220 Server User Manual


 
Servicing Motherboard Components 103
2. Disconnect all power cables.
See “Disconnect Power Cords From the Server” on page 62.
3. Attach an antistatic wrist strap.
4. Disconnect any data cables connected to the cards on the PCIe/XAUI riser being
removed.
Label the cables to ensure proper connection later.
5. Slide the server out of the rack.
See “Extend the Server to the Maintenance Position” on page 63
6. If you are servicing a PCIe/XAUI card, locate its position in the system.
7. Remove the PCI cross beam.
a. Loosen the two captive Phillips screws on each end of the removable PCI
cross beam.
b. Slide the PCI cross beam back to remove it from the chassis.
Two mushroom standoffs secure the removable cross beam to the back of the
system.
FIGURE: Removing the PCIe/XAUI Riser (SPARC Enterprise T5120 Server)