Identifying FRUs in SPARC Enterprise T5220 Servers 201
The following table identifies the power distribution and fan module components in
the server and points to instructions for servicing them.
TABLE: Power Distribution/Fan Module Components (SPARC Enterprise T5220 Servers)
Item FRU Replacement Instructions Notes FRU Name (If Applicable)
1 Paddle card “Servicing Paddle
Cards” on page 171
Includes the top cover
interlock switch.
/SYS/CONNBD
2 Power distribution
board/bus bar
“Servicing Power
Distribution Boards” on
page 160
Bus bar is attached to the
PDB with four screws.
If replacing a defective
PDB, you must move the
bus bar to the new board
and program the chassis
serial number.
/SYS/PDB
3 Power supply backplane “ServicingPowerSupply
Backplanes (SPARC
Enterprise T5220
Servers)” on page 167
This part is bundled
with the power
distribution board.
N/A
4 Power supplies “Servicing Power
Supplies” on page 129
Two power supplies
provide N+1
redundancy.
/SYS/PS0
/SYS/PS1
5 Fan modules “ServicingFan Modules”
on page 123
At least five fan modules
must be installed in the
server.
/SYS/FANBD0/FM0
/SYS/FANBD0/FM1
/SYS/FANBD0/FM2
/SYS/FANBD1/FM1
*
* A fan module might not be present in this slot for some configurations.
6 Fan power boards “Servicing Fan Power
Boards” on page 143
Must be removed to
service the paddle card.
/SYS/FANBD0
/SYS/FANBD1
7 Air duct “Remove the Air Duct”
on page 100
“Install the Air Duct” on
page 101
Must be installed to
provide proper cooling
to the system.
N/A