Fujitsu T5220 Server User Manual


 
Identifying FRUs in SPARC Enterprise T5220 Servers 199
The following table identifies the I/O components in the server and points to
instructions for servicing them.
TABLE: I/O Components (SPARC Enterprise T5220 Servers)
Item FRU Replacement Instructions Notes FRU Name (If Applicable)
1 Top cover “Remove the Top Cover”
on page 67
“Install the Top Cover”
on page 175
Removing top cover if
the system is running
will result in immediate
shutdown.
N/A
2 Hard drive backplane “Servicing the Hard
Drive Backplane” on
page 152
/SYS/SASBP
3 Hard drive cage “Servicing the Hard
Drive Cage” on page 146
Must be removed to
service hard drive
backplane and front
control panel light pipes.
N/A
4 Left control panel light
pipe assembly
“Servicing Front Control
Panel Light Pipe
Assemblies” on page 156
Metal light pipe bracket
is not a FRU.
N/A
5 Hard drives “Servicing Hard Drives”
on page 69
Hard drives must be
removed to service the
hard drive backplane.
See “Eight-Drive
Capable Backplane
Configuration
Reference” on page 78 or
“Sixteen-Drive Capable
Backplane Configuration
Reference” on page 79
6 DVD/USB module “Servicing DVD/USB
Modules” on page 138
Must be removed to
service the hard drive
backplane.
/SYS/DVD
/SYS/USBBD
7 Right control panel light
pipe assembly
“Servicing Front Control
Panel Light Pipe
Assemblies” on page 156
Metal light pipe bracket
is not a FRU.
N/A