Fujitsu T5220 Server User Manual


 
106 SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009
5. Engage the two captive Phillips screws on both sides of the removable PCI cross
beam and tighten the two screws to secure the removable PCI cross beam to the
chassis.
6. Install the top cover.
See “Install the Top Cover” on page 175.
7. Slide the server into the rack.
See “Return the Server to the Normal Rack Position” on page 177.
8. Connect any data cables you removed to service the PCIe/XAUI cards.
9. Connect all power cables.
See “Connect Power Cords to the Server” on page 178.
Related Information
“Remove a PCIe/XAUI Riser” on page 102
“Remove a PCIe or XAUI Card” on page 106
“Install a PCIe or XAUI Card” on page 107
Remove a PCIe or XAUI Card
1. Locate the PCIe/XAUI card that you want to remove. Note its corresponding
riser board.
See “Rear Panel Components and Indicators on SPARC Enterprise T5120 Servers”
on page 8 or “Rear Panel Components and Indicators on SPARC Enterprise T5220
Servers” on page 12.
2. If necessary, note where the PCIe/XAUI cards are installed.
3. Unplug all data cables from the card.
Note the location of all cables for reinstallation later.
4. Remove the riser board.
See “Remove a PCIe/XAUI Riser” on page 102
5. Carefully remove the PCIe/XAUI card from the riser board connector.
6. Place the PCIe/XAUI card on an antistatic mat.
7. If you are not replacing the PCIe/XAUI card, install a PCIe/XAUI filler panel.
SPARC Enterprise T5120: PCIe filler panels are located in the removable PCI
cross beam. Press the filler panel into the cross beam from the rear.