Fujitsu T5220 Server User Manual


 
Identifying FRUs in SPARC Enterprise T5220 Servers 197
The following table identifies the components located on the motherboard and points
to instructions for servicing them.
TABLE: Motherboard Components (SPARC Enterprise T5220 Servers)
Item FRU Replacement Instructions Notes FRU Name (If Applicable)
1 Removable back
panel cross beam
“Servicing PCIe/XAUI
Risers” on page 102
Remove this to service
PCIe/XAUI risers and
cards.
N/A
2 PCIe/XAUI risers “Servicing PCIe/XAUI
Risers” on page 102
Back panel PCI cross
beam must be removed
to access risers.
/SYS/MB/RISER0
/SYS/MB/RISER1
/SYS/MB/RISER2
3 PCIe filler panel “Servicing PCIe/XAUI
Risers” on page 102
Must be installed in
blank PCI slots.
N/A
4 Battery “Servicing the Battery”
on page 112
Necessary for system
clock and other
functions.
/SYS/MB/V_VBAT
5 FB-DIMMs “Identify Faulty
FB-DIMMs Using the
show faulty
Command” on page 83
“Identify Faulty
FB-DIMMs Using the
FB-DIMM Fault Locator
Button” on page 83
See configuration rules
before upgrading
FB-DIMMs.
See “FB-DIMM Configuration
Guidelines” on page 95
6 SCC module “Servicing the SCC
Module” on page 114
Contains host ID, MAC
addresses, and service
processor configuration
data.
/SYS/MB/SC/SCC_NVRAM
7 Motherboard
assembly
“Servicing the
Motherboard Assembly”
on page 117
Must be removed to
access power
distribution board,
power supply
backplane, and paddle
card.
/SYS/MB