102 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
Servicing PCIe/XAUI Risers
These topics explain how to service the riser units that support PCIe and XAUI cards
and how to remove and install the I/O cards themselves.
■ “PCIe/XAUI Riser Overview” on page 102
■ “Remove a PCIe/XAUI Riser” on page 102
■ “Install a PCIe/XAUI Riser” on page 104
■ “Remove a PCIe or XAUI Card” on page 106
■ “Install a PCIe or XAUI Card” on page 107
■ “PCIe/XAUI Card Configuration Reference for SPARC Enterprise T5120 Servers”
on page 110
■ “PCIe and XAUI Card Reference for SPARC Enterprise T5220 Servers” on page 111
PCIe/XAUI Riser Overview
PCIe/XAUI cards are installed on vertical risers. You must remove the PCI cross
beam and relevant riser to access a PCIe/XAUI card.
Caution – This procedure requires that you handle components that are sensitive to
static discharge. This sensitivity can cause the component to fail.
Caution – Ensure that all power is removed from the server before removing or
installing expansion cards. You must disconnect the power cables before performing
this procedure.
You must remove PCIe riser 2 when servicing the SCC module.
You must remove all three PCIe/XAUI risers when servicing the motherboard.
▼ Remove a PCIe/XAUI Riser
1. Power off the server.
See “Removing Power From the System” on page 60.