102 SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009
Servicing PCIe/XAUI Risers
These topics explain how to service the riser units that support PCIe and XAUI cards
and how to remove and install the I/O cards themselves.
“PCIe/XAUI Riser Overview” on page 102
“Remove a PCIe/XAUI Riser” on page 102
“Install a PCIe/XAUI Riser” on page 104
“Remove a PCIe or XAUI Card” on page 106
“Install a PCIe or XAUI Card” on page 107
“PCIe/XAUI Card Configuration Reference for SPARC Enterprise T5120 Servers”
on page 110
“PCIe and XAUI Card Reference for SPARC Enterprise T5220 Servers” on page 111
PCIe/XAUI Riser Overview
PCIe/XAUI cards are installed on vertical risers. You must remove the PCI cross
beam and relevant riser to access a PCIe/XAUI card.
Caution This procedure requires that you handle components that are sensitive to
static discharge. This sensitivity can cause the component to fail.
Caution Ensure that all power is removed from the server before removing or
installing expansion cards. You must disconnect the power cables before performing
this procedure.
You must remove PCIe riser 2 when servicing the SCC module.
You must remove all three PCIe/XAUI risers when servicing the motherboard.
Remove a PCIe/XAUI Riser
1. Power off the server.
See “Removing Power From the System” on page 60.