HP (Hewlett-Packard) tc2100 Server User Manual


 
Chapter 5 Error Messages
35
0231 Shadow Ram Failed
(at offset)
POST has detected an incorrectly installed DIMM or the
failure of one or more DIMMs.
To correct this:
1. If additional memory was just installed in your Server,
please verify the installation conforms to the description
in the Installation Guide.
2. If this error is reported when no additional memory has
just been installed, restart the Server.
3. If the error persists, contact your service representative.
0232 Extended RAM Failed
(at address line)
POST has detected an incorrectly installed DIMM or the
failure of one or more DIMMs.
To correct this:
1. If additional memory was just installed in your Server,
please verify the installation conforms to the description
in the Installation Guide.
2. If this error was reported when no additional memory
has been just installed, restart the Server.
3. If the error persists, contact your service representative.
0233 Memory type mixing detected POST has detected one or more DIMMs are not the correct
type, or the correct speed for this Server.
To correct this:
1. If additional memory has just been installed in your
Server, please verify the correct DIMM type and speed
was used for this Server.
2. Refer to the DIMM description in the Installation Guide.
3. If this error is reported when no changes to memory has
occurred, restart the Server.
4. If this error persists with no other error messages,
contact your service representative.
8100 Memory decreased in Size The BIOS has detected the usable memory is much less than
the total memory available. Typically, this indicates a DIMM
is defective or is not properly seated in the DIMM slot.
To correct this:
1. Ensure each DIMM is correctly inserted into the DIMM
slot.
2. Ensure both latches are completely closed on each
DIMM.
3. If all latches are completely closed, and the DIMMs are
correctly seated in the DIMM slots, go to the next step.
4. Replace each DIMM with a known good DIMM,
rebooting the Server between each replacement, to
determine which DIMM is defective.
5. If this error persists after you have replaced all the
DIMMs with no other error messages, contact your
service representative. You may have to replace the
system board.