HP (Hewlett-Packard) tc2100 Server User Manual


 
7
1 Specifications
Technical Specifications
The specifications listed below for HP Tower Server tc2100 may vary if you install a mass storage device in
your server that has more stringent environmental limits. Ensure the operating environment for your server is
suitable for all of the mass storage devices being used.
Environmental
Temperature
Operating
5° to 35° C (41° to 95° F)
Non-operating
-40° to +65° C (-40° to +149° F)
Humidity
Operating
20% to 80% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing
Altitude
Operating
-30 to 3,000 m (~ 10,000 ft)
Non-operating
-30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum Operating
1066 BTU/hr
Weight and Dimensions
Weight
Basic configuration approx. 13.5 kg. (30 lbs) – excludes keyboard and monitor.
Fully loaded approx. 22.6 kg. (50 lbs) – excludes keyboard and monitor.
Height
46.0 cm (18.11 inches)
Width
20.5 cm (8.07 inches)
Depth
46.7 cm (18.39 inches)
Power Supply Specifications
Parameter Characteristics
Input Type Manual voltage selection
Input – Maximum Range 100 to 127 VAC @ 50/60 Hz
200 to 240 VAC @ 50/60 Hz
Operating Current 100 to 127 VAC: 7.0 A
200 to 240 VAC: 3.5 A
In-rush Current 90 A (cold) 120 A (warm)
Operating Power 250 W Continuous