9 - 6
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description (page 9-1) for additional
information. Minimum and Maximum lengths = 0-80. Minimum Default = 3, Maximum Default = 80.
Code 39 Redundancy
If you are encountering errors when reading Code 39 bar codes, you may want to adjust the redundancy count. Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan
the Code 39 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart
inside the back cover of this manual, then scanning Save. Default = 0.
Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as
PAR AF.
Note: Trioptic Code (page 9-62) must be turned off while scanning Code 32 Pharmaceutical codes.
Validate, but Don’t Transmit
Validate and Transmit
Minimum Message Length
Maximum Message Length
Code 39 Redundancy
On