Honeywell 2700 Scanner User Manual


 
1 - 2
Power Installation
The Power Supply (AC/DC) should be connected to an AC outlet that is free of electrical noise (clean). A qualified electri-
cian can determine the amount of electrical noise on the AC line. All power supplies must be properly grounded.
Honeywell recommends using a switched AC outlet. The switch should be located on the operator's side of the checkout
counter in close proximity to the Stratos bioptic to facilitate calibration and service of the unit.
Note: The power supply should never be disconnected from the Stratos bioptic without first disconnecting the AC power.
EAS Considerations
Do not install any large iron fixtures, such as steel support poles, near the Stratos bioptic. Doing so may re-shape the EAS
tag deactivation field. See EAS Settings beginning on page 10-1 for complete EAS information.
Power from Host
The Stratos 2700 can be powered from a USB PlusPower host or other host system that can supply at least 12 Volts at
1.5Amps using special cables. (This is the typical voltage and current available on a Green USB Plus Power connector).
It may also be possible to connect and power an auxiliary scanner, a BOB camera, or other peripheral. Please consult with
a Honeywell representative to review plans to power these or other auxiliary devices when the unit will be powered from the
host. See USB Host Power on page 3-5 for power conservation settings.
Unpacking Your Device
After you open the shipping carton containing the product, take the following steps:
Check for damage during shipment. Report damage immediately to the carrier who delivered the carton.
Make sure the items in the carton match your order.
Save the shipping container for later storage or shipping.
1. Make sure the shipping box is top-side up before opening.
2. Carefully remove the platter and store it in a safe location until the unit is properly
installed into the checkout counter.
3. Remove all loose packing materials from the box.
4. Lift the Stratos bioptic out of the box by grasping each end of the unit and lifting directly
up.
Note: Do not remove the scanner from the box by grabbing the shipping foam. This can
result in the unit falling.
5. Remove the shipping foam from around the scanner.
Note: Retain all packing materials in the event you need to re-pack the unit.
6. Remove the protective film from the top side platter surface, vertical scan window, and horizontal scan window.
Configuring the 2700
If the unit has not already been pre-configured with the proper POS interface and selectable options, program the configuration
now. You may do so using EZConfig-Scanning (see EZConfig-Scanning Introduction on page 12-2), or by scanning the pro-
gramming bar codes in this manual.