Appendix B • Installing the indoor equipment using dial-up commissioning
92
1033295-0001 Revision 2
10. Select the Manual fine pointing mode radio button.
11. Select Start Test. Adjust the antenna to achieve maximum
transmit isolation.
12. When the unit consistently passes the manual transmit test,
bolt the antenna securely before going to Step 13.
13. After the antenna is bolted, select
Stop Test. See Figure 81.
14. Then select the
Automatic radio button and select Start Test
to start the automatic ACP test. See Figure 82.
15. Make sure the test passes.
16. Select Exit after passing the test.
Figure 81: Manual cross-pol passed; select Stop Test
Figure 82: Auto cross-pol