Hughes DW6000 Network Router User Manual


 
Appendix C • Installing the DW6000 using Installer Console
1033295-0001 Revision 2
115
Verifying software
download
If the DW6000 is configured correctly for outroute reception and
SQF is greater than 30, it will acquire the outroute. As soon as the
DW6000 acquires the outroute, it begins to look for messages
from the Software Download server in the data stream to perform
software download.
1. To monitor software download (SDL) progress, enter f at the
Main Menu prompt to select Software Download Monitor.
2. The following message is displayed at the bottom of the
screen:
SDL Initialization complete. Awaiting first heartbeat msg.
This message is dynamically updated. It indicates that SDL
has started and is waiting to connect with the SDL server.
3. If SDL does not progress beyond this message, check the
following:
The SDL control channel’s multicast IP address
Return to the
Main Menu.
–Enter
b to view the current configuration
Check that the
SDL Control Channel Multicast Address is
correct. If not, enter the correct address.
The LED lights to ensure they are on. See Power up and read
the DW6000 LED display on page 101 and Communicating
with the DW6000 via Hyperterminal on page 103.
4. When the DW6000 receives a message from the SDL server,
the following message is displayed:
Received first heartbeat message.
5. If there is no progress beyond this message, check the return
path. When operating normally, the following message is
displayed:
Note: It may be 20 minutes before the first heartbeat message is
received.
Received File/Group message. Reconciling files...
MM loading...
IP loading...
...
All files downloaded. Notifying CFM.