PSF Terminates When Initialized
263
PSF Terminates When Initialized
If PSF terminates when you initialize it for IPDS printing and issues
message PQT3603, check for the following error codes:
• Code 10 means an incorrect RMTSYS or RMTLOCNAME (V3R2,
V3R7, or V4R1) has been specified for the printer.
• Code 15 means that PSF timed out waiting for the printer’s
response. Check the value you entered for Activation Timer
when using WRKAFP2, CRTPSFCFG (V3R2), or CRTDEVPRT
(V3R7 or V4R1).
• Codes 20-39 indicate a general communications failure. Make
sure all of the components in your network are operational,
such as routers. If necessary, call IBM technical support.
• Codes 40-59 indicate a logic error between PSF and the printer
control unit. Contact IBM technical support.
Spooled Print File Remains In PND Status
Check the output queue with the command:
WRKOUTQ queuename
This typically indicates that PSF is waiting for a response from the
printer. This can be verified by displaying the QSPL subsystem,
WRKACTJOBSBS (QSPL). If the status of the PDJ job for the printer
is SELW, then PSF is waiting for a response from the printer. Make
sure that the printer is in ONLINE mode and that all network
connections (for example, routers) between the iSeries and the
printer are active.