IBM 81Y Computer Hardware User Manual


 
Symptom-to-FRU index 151
180-XXX-005 (Failed SCSI
Backplane LED test)
1. SCSI Backplane
2. SCSI Backplane Cable
3. I/O Legacy Board
180-XXX-006 (Memory Board
LED test)
1. Memory Board
2. Processor/PCI Board
3. I/O Legacy Board
201-XXX-0NN (Failed Memory
test, see "Memory Settings" on
page 49.) NN = DIMM location.
1. DIMM Location J1-J16
2. Memory card
201-XXX-999 (Multiple DIMM
failure, see error text.)
1. See error text for failing DIMMs
2. Memory card
202-XXX-001 (Failed System
Cache test)
1. VRM 1
2. Microprocessor CPU 1
202-XXX-002 (Failed System
Cache test)
1. VRM 2
2. Microprocessor CPU 2
202-XXX-003 (Failed System
Cache test)
1. VRM 3
2. Microprocessor CPU 3
202-XXX-004 (Failed System
Cache test)
1. VRM 4
2. Microprocessor CPU 4
206-XXX-000 (Failed Diskette
Drive test)
1. Cable
2. Diskette Drive
3. I/O Legacy Board
215-XXX-000 (Failed IDE CD-
ROM test)
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. I/O Legacy Board
217-XXX-000 (Failed BIOS Fixed
Disk test)
Note: If RAID is configured,
the fixed disk number
refers to the RAID
logical array.
1. Fixed Disk 1
217-XXX-001 (Failed BIOS
Fixed Disk test)
Note: If RAID is configured,
the fixed disk number
refers to the RAID
logical array.
1. Fixed Disk 2
217-XXX-002 (Failed BIOS
Fixed Disk test)
Note: If RAID is configured,
the fixed disk number
refers to the RAID
logical array.
1. Fixed Disk 3
Error Code/Symptom FRU/Action