IBM 81Y Computer Hardware User Manual


 
158 Hardware Maintenance Manual: xSeries 250
1301 (cable to front panel not
found)
1. Cable
2. Front Panel
3. Power Switch Assembly
4. I/O Legacy Board
1302 (cable from system board
to power on and reset switches
not found)
1. Cable
2. Power Switch Assembly
3. I/O Legacy Board
1303 (cable from system board to
power backplane not found)
1. Cable
2. Power Backplane
3. I/O Legacy Board
1304 (cable to diagnostic LED
board not found)
1. Cable
2. Diagnostic LED Board
3. Power Switch Assembly
4. I/O Legacy Board
1600 (The Service Processor is
not functioning) Do the
following before replacing a
FRU:
1. Ensure that a jumper is not
installed on J51.
2. Remove the ac power to the
system, wait 20 seconds;
then, re-connect the ac
power. Wait 30 seconds;
then, power-on the system.
1. I/O Legacy Board
2. Processor/PCI Board
1601 (The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond at the
start of POST.) Do the following
before replacing a FRU:
1. Remove the ac power to the
system, wait 20 seconds;
then, re-connect the ac
power. Wait 30 seconds;
then, power-on the system.
2. Flash update the Service
Processor.
1. I/O Legacy Board
2. Processor/PCI Board
1762 (Fixed Disk Configuration
error)
1. Fixed Disk Drive
2. Fixed Disk Cables
3. Run Configuration/Setup
4. Fixed Disk Adapter
5. SCSI Backplane
6. I/O Legacy Board
Error Code/Symptom FRU/Action