IBM 81Y Computer Hardware User Manual


 
Diagnostics 39
PCNTNW-NW-
071
The matching virtual adapter could not be found.
Explanation: You tried to load another instance of the driver with a
different I/O address. This new adapter could not be found.
Action: Verify that you installed an IBM 10/100 Fault Tolerant Adapter
and make sure that the adapter is seated correctly. If the adapter is
seated correctly, go to “Starting the diagnostic programs” on page 26 to
run the diagnostic programs.
PCNTNW-NW-
072
A resource tag is unavailable.
Explanation: The driver tried to allocate some resources that were not
available.
Action: Add more memory, or free some memory resources in the server.
Then, restart the server.
PCNTNW-NW-
073
Unable to allocate memory
Explanation: The driver failed to allocate the memory needed for
normal operation.
Action: Add more memory, or free some memory resources in the server.
Then, restart the server.
PCNTNW-NW-
074
The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware
interrupt. The attempt was not successful.
Action: Verify that the Ethernet controller is enabled. If the Ethernet
controller is enabled, go to “Starting the diagnostic programs” on page
26 to run the diagnostic programs.
If you have an Ethernet adapter installed, make sure that the adapter
does not share an IRQ with any other device.
PCNTNW-NW-
075
The Multiple Link Interface Driver (MLID) cannot be registered with
the Link Support Layer (LSL).
Explanation: An error occurred while the driver was trying to register
with the LSL.
Action: Check the version of the NetWare or IntraNetWare Operating
System. Make sure that this driver is correct for the version of NetWare
or IntraNetWare that you are using. Restart the server.
PCNTNW-NW-
079
The Multiple Link Interface Driver (MLID) did not initialize MSMTx
Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, go to “Starting the
diagnostic programs” on page 26 to run the diagnostic programs.
PCNTNW-NW-
086
The driver parameter block is too small.
Explanation: The driver parameter block is too small.
Action: Restart the server. If the problem persists, go to “Starting the
diagnostic programs” on page 26 to run the diagnostic programs.
PCNTNW-NW-
087
The media parameter block is too small.
Explanation: The driver media parameter block is too small.
Action: Restart the server. If the problem persists, go to “Starting the
diagnostic programs” on page 26 to run the diagnostic programs.
Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller.