IBM 81Y Computer Hardware User Manual


 
42 Hardware Maintenance Manual: xSeries 250
pnt0-12 Device failed checksum test!
Explanation: The driver cannot find an Ethernet controller.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run
the diagnostic programs.
pnt0-13 add_intr_handler failed! Interrupts already enabled.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify the hardware settings.
pnt0-14 Cannot locate hardware.
Explanation: The SunSoft Solaris driver cannot find any Ethernet controller.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run
the diagnostic programs.
pnt0-15 No more devices to open.
Explanation: The SunSoft Solaris driver cannot find any more Ethernet controllers. Action:
Verify that additional IBM 10/100 Fault Tolerant Adapters are present or replace the Ethernet
adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-17 Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has been reset due to a device fault.
Action: Verify that additional IBM 10/100 Fault Tolerant Adapters are present or replace the
Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-19 IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings
pnt0-20 add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action:
Modify the hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-21 add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action:
Modify the hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22 add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify the hardware settings. Run the NETCONFIG program to search for another
Ethernet controller.
Table 5. UNIX LLI driver messages for the Ethernet controller.