IBM 81Y Computer Hardware User Manual


 
Symptom-to-FRU index 155
POST error codes
In the following error codes, X can be any number or letter.
On Off Standby mode or dc
problem.
1. Move jumper on J23 to pins 2-3 to
bypass power control. If the DC
Good LED comes on, press
Ctrl+Alt+Delete. Watch the screen
for any POST errors. Check the
System Error Log for any listed
problems. If
the system powers up with no
errors:
a. Power Switch Assembly
2. Remove the adapters and
disconnect the cables and power
connectors to all internal and
external devices. Power-on the
system. If the DC Good LED
comes on, replace the adapters and
devices one at a time until you
isolate the problem.
3. Power Supply
4. Power Backplane
5. I/O Legacy Board
6. Processor Board
On On Power is OK. N/A
Error Code/Symptom FRU/Action
062 (Three consecutive boot
failures using the default
configuration.)
1. Run Configuration/Setup
2. Battery
3. I/O Legacy Board
4. Processor/PCI Board
5. Processor
101, 102 (System and processor
error)
1. I/O Legacy Board
2. Processor/PCI Board
106 (System and processor error) 1. I/O Legacy Board
2. Processor/PCI Board
111 (Channel check error) 1. Failing adapter
2. DIMM
3. I/O Legacy board
114 (Adapter read-only memory
error)
1. Failing adapter
2. Run diagnostics
AC Good
LED
DC Good
LED
Description FRU/Action