Specifying DNS query timeout setting (mode 367)
You can specify the time until a timeout of the DNS server connection oc-
curs.
Factory settings
Specifying settings
The shaded cells represent the factory settings. The page numbers on the
right refer to the descriptions of the corresponding functions.
Bit 7 6 5 4 3 2 1 0
Setting 0 0 1 0 0 0 0 0 (HEX: 20)
Bit Description Setting Description Page
Refer-
ence
7, 6, 5, 4,
3
Specifies the time until a
timeout of the DNS server
connection occurs.
00001 20 seconds ---------
00010 40 seconds
00011 80 seconds
00100 160 seconds
10101 320 seconds
00110 640 seconds
Other *Do not specify other set-
tings than the above.
2, 1, 0 -----------------------------
000 *Do not change these bits
when specifying settings for