Lenovo 3809 Server User Manual


 
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Hardware Maintenance Manual to determine which components are customer replaceable units
(CRUs) and which components are field replaceable units (FRUs).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
0068002 CMOS battery cleared.
1. Reseat the battery.
2. Clear the CMOS memory.
3. Replace the following components one at a time,
in the following order, restarting the server after
each one:
a. Battery
b. (Trained service technician only) System
board.
2011001 PCI-X PERR
1. Reseat all affected adapters.
2. Update the PCI adapter firmware.
3. Remove the adapter.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Adapter
b. (Trained service technician only) System
board
2018001 PCI Express uncorrected or uncorrected error
1. Reseat all affected adapters.
2. Update the PCI adapter firmware.
3. Remove the adapter.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Adapter
b. (Trained service technician only) System
board
182 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide