Table 1. Features and specifications (continued)
Drives (depending on the model):
v Optical drives: SATA
v Hard disk drives: SAS and SATA
Drive bays (depending on the model):
v Three 5.25-in. bays (one half-high
DVD-ROM drive installed). Optionally
you can install one full-high or two
half-high internal tape drives in bays 2
and 3.
v One of the following:
Four 3.5-inch simple-swap SATA
drives
Four 3.5-inch hot-swap SAS or SATA
drives
Eight 2.5-inch hot-swap SAS or
SATA drives
Integrated functions:
v Integrated Management Module (IMM),
which provides service processor
control and monitoring functions, video
controller, and (when the optional virtual
media key is installed) remote
keyboard, video, mouse, and remote
hard disk drive capabilities
v Broadcom BCM5709 Gb Ethernet
controller with TCP/IP Offload Engine
(TOE) and Wake on LAN
®
support
v Onboard SATA controller (simple-swap
models)
v Seven Universal Serial Bus (USB) 2.0
ports (two front and four rear of the
chassis), and one for the internal USB
tape drive.
v Two Ethernet ports
v One System Management RJ-45 on the
rear to connect to a
systems-management network. This
systems-management connector is
dedicated to the IMM functions. This
connector is active with or without the
optional Virtual Media Key installed.
v One serial port
v Six SATA ports (four through the iPASS
connector for simple-swap drives and
two for the optical drives)
Acoustical noise emissions:
v Sound power, idling: 5.5 bel
v Sound power, operating: 6.0 bel
Environment:
v Air temperature:
Server on: 10° to 35°C (50° to 95°F)
Altitude: 0 to 915 m (3000 ft)
Server on: 10° to 32°C (50° to 90°F)
Altitude: 0 to 915 m (3000 ft) to 2134
m (7000 ft)
Server on: 10° to 28°C (50° to 83°F)
Altitude: 2134 m (7000 ft) to 3050 m
(10000 ft)
Server off: 5° to 45°C (41.0° to
113°F)
Shipping: -40° to 60°C (-40° to
140°F)
v Humidity (operating and storage):
Server on: 20% to 80%, Maximum
dew point 21°C, Maximum rate of
change 5°C/hr.
Server off: 8% to 80%, Maximum
dew point 27°C
Heat output:
Approximate heat output in British thermal
units (Btu) per hour:
v Minimum configuration: 693 Btu per
hour (203 watts)
v Maximum configuration: 2788 Btu per
hour (817 watts)
Chapter 3. What is included with your server