Power Cable
The power cable is a 14.5-foot, 18 A
WG stranded
cable. The connector is terminated at one end with a
6-position Molex 39-01-2060 connector. The other end of
the cable is terminated with a bare wire that should be
connected to a DC power source. Figure D-9 shows the
wire colors. The power source can be either a single
source of +24 Vdc or up to two sources of –
48 Vdc
(A and B). Y
ou cannot connect +24 Vdc and –
48 Vdc to
the same unit. See the installation instructions in
Chapter 2, Installation.
Figure D-9. DC Power Cable
(Feature Number 3100-F1-520)
Power Input Connector
The required input power connector leads are shown in
Table D-10.
Table D-10
DC Power Connector
Signal
Pin Number
–48 Vdc Return 1,2
–48 Vdc A 6
–48 Vdc B 5
+24 Vdc 5
+24 Vdc Return 4
Chassis Ground 3