Paradyne 316x Modem User Manual


 
ACCULINK 316x DSU/CSU
3-32 December 1996 3160-A2-GB22-10
Selecting the Number of Trap Managers
If
you intend to issue traps to an SNMP manager(s)
from this device, you must specify the number of SNMP
managers that are to receive the traps.
To specify the number of SNMP managers to receive
traps from this device,
1. Press F3 to select Cnfig from the top-level menu
screen.
F1
DS
U E
SF
Stat Test Cnfig
F2
F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key
. Use the scroll keys, if necessary
.
F1
Load from:
Activ Cust Fact1
F2
F3
3. Press F1 to select Edit.
F1
Choose Funct:
Edit Save
F2
F3
4. Press the key from the Edit screen to display
the SNMP selection.
F1
Edit:
DTE Port NET
F2
F3
5.
Press F3 to select SNMP
.
F1
Edit:
User Alarm SNMP
F2
F3
6.
Press F2 to select T
rap from the SNMP Config
screen.
F1
SNMP Config:
Gen Trap
F2
F3
7. Select the number of SNMP managers to receive
traps (from 1 through 6) by using the appropriate
function key
. Use the scroll keys, if necessary
.
F1
Num Trap Mgrs:1
Next 1 2
F2
F3
Differences
Using the Async T
erminal: T
o set the
number of trap managers, select Trap Options from the
main/configuration/edit/snmp menu. Figure 3-23 shows
an example of the screen that appears.