Dial Out User Statistics Window 123
Access Server Administrators’ Reference Guide 8 • Dial Out
• requireV42bis(2)—v.42bis compression is mandatory, otherwise disconnect.
• v44(3)—allow v.42bis and v.44 data compression. Will negotiated for v.44 compression first, if that’s not
available, then it will try v.42bis, and if neither is available, will use no compression.
Billing Delay (modemBillingDelay)
The number of seconds after answering the call during which the modem should be silent.
Status (modemStatus)
This is the status of the modem profile entry. “valid(1)” means the entry is valid. Set the profile to “destroy(2)”
to remove the profile.
View modem profile
To view and/or modify a modem profile, click on the profile ID in the table and you will see the following
page. Settings can be modified and submitted on this page. Any changes will take place on the next call to the
location(s) which are using this profile. See the section
“Add Modem Profile” on page 121 for an explanation
of each field.
Figure 49. View/modify modem profile.
Dial Out User Statistics Window
Clicking on the state link of an individual call will show the statistics for that call. The hyperlink headings DSP
Link, and WAN Link shown below point to the DSP and WAN information used for the outbound call. For
specific details about the function of parameters defined under these sections, refer to the appropriate section
under the access server Configuration menu.
The Dial Out Statistics window is where you can view the following:
• Unique ID information
• Session information
• PPP statistics (for location based calls)
• IP statistics (for location based calls)