Dial Out User Statistics Window 126
Access Server Administrators’ Reference Guide 8 • Dial Out
• pppClose(8)—This reason will be given after PPP is initiated and the connection is disconnected. An exam-
ple would be if LCP negotiations failed.
• lcpClose(9)—close initiated by LCP. This is a normal shutdown of a call.
• loginTimeOut(10)—exceeded time limit to login.
• userTerminated(11)—the TCP connection was terminated from the remote side.
• maxNumCalls(21)—exceeds the maximum number of channels that can be allocated to the same call.
• maxLoginAttempts(32)—exceeded maximum login attempts as defined under the dial-out link
• noDspAvailable(45)—when the server tried to allocate a DSP for an outbound call but no available DSP’s
were available.
• papAuthenticationFailure(49)—invalid username/password combination for tcp based calling.
• exceedsMultiLinkLimit(64)—exceeds the maximum multilink calls set in the location table.
• sessionTimeout(66)—the length of the connection exceeds the session time limit allowed.
• noAnswer(85)—the remote modem did not answer the call.
• userBusy(86)—the remote location is busy and did not answer the call
• noChannelAvail(87)—no channels on the T1/E1 port were available to dialout with.
The following are internal access server errors. Please contact technical support if you see these termination rea-
sons on a consistent basis.
• noPoll(12)
• ipcPutMsgErr(13)
• pollErr(15)
• ioctlErr(16)
• pppPutMsgErr(17)
• dspIoctlErr(18)
• timerErr(19)
• pppOpenErr(22)
• pppLinkErr(25)
• tcpOpenErr(26)
• tcpPushErr(27)
• tcpPutMsgErr(28)
• invalidPrim(29)
• noTimers(33)
• tcpLinkErr(34)
• dspLinkErr(35)