Using a browser to complete Model 6511RC configuration 67
Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Example 2
Map E1 Port 2 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.
Map E1 Port 2 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.
Solution:
1. Under E1 Number, select port2(2) from the drop-down menu (see figure 50).
2. Under E1 Slots, enter 1-32 in the text box.
3. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.
4. For toH110(5), under H.110 slots, enter 65-96 in the text box.
5. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.
6. For fromH110(5), under H.110 slots, enter 97-128 in the text box.
Figure 50. Define a Mapping table for example 2
7. Click the
Define
button.
8. Verify your new mapping appears in the Defined Mappings table (see figure 51).
Figure 51. Defined Mappings table for example 2
9. Examine the new mapping to verify that it was entered and recorded correctly.
You have completed the configuration for example 2.