Using a browser to complete Model 6511RC configuration 73
Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Example 2
Map TUG-3 or AU-3 no. 2, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port
1timeslots 97-128.
Solution:
1. For the value of the first parameter under SDH Channel, select either TUG3-2(2) or AU3-2(2) from the
drop-down menu.
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu.
3. For the value of TU-12 select TU12-1(1) from the drop-down menu.
4. Under E1 Slots, enter 1-32 in the text box.
5. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.
6. For toH110(5), under H.110 slots, enter 65-96 in the text box.
7. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.
8. For fromH110(5), under H.110 slots, enter 97-128 in the text box.
9. Click the
Define
button.
10. Verify your new mapping appears in the Defined Mappings table.
11. Examine the new mapping to ensure it was entered and recorded correctly.
You have completed the configuration for example 2.
Example 3
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 received, timeslots 1 - 32 to H.110 Port 4 timeslots 1-
32.
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 transmitted, timeslots 1 - 32 from H.110 Port
4timeslots 33- 64.
Solution:
1. For the value of the first parameter under SDH Channel, select either TUG3-1(1) or AU3-1(1) from the
drop-down menu.
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu.
3. For the value of TU-12 select TU12-3(3) from the drop-down menu.
4. Under E1 Slots, enter 1-32 in the text box.
5. For toH110(5), under H.110 Number, select port4(4) from the drop-down menu.
6. For toH110(5), under H.110 slots, enter 1-32 in the text box.
7. For fromH110(5), under H.110 Number, select port4(4) from the drop-down menu.
8. For fromH110(5), under H.110 slots, enter 33-64 in the text box.