Polycom MGC-50/MGC-100 Network Router User Manual


 
Chapter 4 - Hardware Description
4-26
The different types of Functional Modules are used to produce a variety of
configurations. In the MGC-50 up to eight individual Functional Modules can
be used to build the desired configuration. In the MGC-100, 16 modules can
be used.
Figure 4-12 shows the general design of the Functional Modules. The
components that are common to all Functional Modules are shown in detail in
the figure and are described in Table 4-5 on page 4-27.
MUX Module Multiplexes and
demultiplexes audio, data,
video, and control
information; performs
channel aggregation (inverse
multiplexing).
Up to 16 ports
MUX+10 Multiplexes and
demultiplexes audio, data,
video, and control
information; performs
channel aggregation,
enables Encryption.
18 channels at
128Kbps
MUX+20 Multiplexes and
demultiplexes audio, data,
video, and control
information; performs
channel aggregation,
enables Encryption.
128 36 channels at
128Kbps
MUX+40 Multiplexes and
demultiplexes audio, data,
video, and control
information; performs
channel aggregation,
enables Encryption.
72 channels at
128Kbps
Data Module Performs data routing and
conference control.
T.120 standard card
- 12 ports
T.120-24 card - 24
ports
Table 4-4: MGC Functional Modules Description
Functional Module Function Port capacity