Raritan Engineering DOMINION KXII Switch User Manual


 
134 DOMINION KX II USER GUIDE
Factory Reset (KX II Local Console Only)
Note: This feature is available only on the Dominion KX II Local Console.
The Dominion KX II offers several types of reset modes from the Local Console user interface.
Note: It is recommended that you save the audit log prior to performing a factory reset. The audit
log is deleted when a factory reset is performed and the reset event is not logged in the audit log.
For more information about saving the audit log, please refer to
Audit Log.
To perform a factory reset:
1. Select Maintenance > Factory Reset. The Factory Reset page opens:
Figure 103: Factory Reset (Local Console Only)
2. Select the appropriate reset option.
Full Factory Reset: Removes the entire configuration and resets the unit completely to
the factory defaults. Please note that any management associations with CommandCenter
will be broken. Because of the complete nature of this reset, you will be prompted to
confirm the factory reset.
Network Parameter Reset: Resets the network parameters (from Device Settings >
Network Settings) of the unit back to the default values:
IP auto configuration
IP Address
Subnet Mask
Gateway IP address
Primary DNS server IP address
Secondary DNS server IP address
Discovery Port
Bandwidth Limit
LAN Interface Speed & Duplex
Enable Automatic Failover
Ping Interval (seconds)
Timeout (Seconds)
You will be prompted to confirm this action because all network settings will be
permanently lost.
3. Click Reset to continue. You will be prompted to confirm the factory reset.
4. Click the Really Reset button to proceed. Upon completion, the Dominion KX II unit is
automatically restarted.