Raritan Engineering KX2-832 Switch User Manual


 
Chapter 7: Device Management
135
Trap Name Description
userModified A user account has been modified.
userPasswordChanged This event is triggered if the password of any user
of the device is modified.
userSessionTimeout A user with an active session has experienced a
session termination due to timeout.
userUploadedCertificate A user uploaded a SSL certificate.
vmImageConnected User attempted to mount either a device or image
on the target using Virtual Media. For every attempt
on device/image mapping (mounting) this event is
generated.
vmImageDisconnected User attempted to unmount a device or image on
the target using Virtual Media.
Power Supply Setup
The Dominion KX II provides dual power supplies, and can automatically
detect and provide notification regarding the status of these power
supplies. Use the Power Supply Setup page to specify whether you are
using one or both of the power supplies. Proper configuration ensures
that the Dominion KX II sends the appropriate notifications should a
power supply fail. For example, if power supply number one fails, the
power LED at the front of the unit will turn red.
To enable automatic detection for the power supplies in use:
1. Choose Device Settings > Power Supply Setup. The Power Supply
Setup page opens.