Roland VS-2400 Switch User Manual


 
89
Algorithm List
Algorithm List
Parameter (full name) Setting Function
CmpA, CmpB
(Compressor): Compresses the entire output signals when the input volume has exceeded a
preset value.
(Limiter): Suppresses the volume of the section where the input volume has exceeded the
preset value.
Sw (Switch) On, Off Turns the compressor/limiter on or off.
Thrsh (Threshold Level) -60 - 0 dB Sets the level at which the compressor/limiter starts taking
effect.
Ratio (Ratio) 1.5:1, 2:1, 4:1, 100:1 Sets the compression ratio applied when threshold level
(Thresh) is exceeded.
Attack (Attack Time) 0–100 Sets the time from when the input level exceeds the
threshold level to when the effect begins to apply.
Release (Release Time) 0–100 Sets the time from when the input level drops below the
threshold level to when the effect ceases to apply.
Level (Output Level) -60–12 dB Sets the volume of the compressor/limiter sound.
Detect (Detect In) A, B, Link Selects Input A or B for controlling compressor/limiter. Set
this to “Link” for controlling by the input at a greater level.
NS (Noise Suppressor): Mutes noise in the silent mode.
Sw (Switch) On, Off Turns the noise suppressor on or off.
Thresh (Threshold) 0–100 Sets the level to start muting noise.
Release (Release) 0–100 Sets the time over which the volume will drop to 0 after the
noise starts being muted.
Detect (Detect In) A, B, Link Selects the input (Input A/Input B) for controlling Noise
Suppressor. Set this to “Link” for controlling by the input at
a greater level.
2400_app_e.book 89 ページ 2005年4月28日 木曜日 午後1時14分