99
Algorithm List
Algorithm List
Cmp (Compressor):Compresses the entire output signals when the input volume exceeds a specified value.
SW (Switch) On, Off Turns the compressor on or off.
Low Thre (Low Threshold) -24–0 dB
Sets the volume at which the compressor for the low frequency band starts working.
Low Ratio (Low Raito) 1:1.0–1:16, 1:INF Sets the ratio at which the output in the low frequency band is suppressed
when the input level has exceeded the low threshold level.
Low Atck (Low Attack) 0–100 ms Sets the time until when the low frequency band compressor starts working
after the input level has exceeded the low threshold level.
Low Rel (Low Release) 50 ms–5.000 s Sets the time until when the low frequency band compressor stops working
after the input level has dropped below the low threshold level.
Mid Thre (Middle Threshold) -24–0 dB Sets the volume at which the compressor in the middle frequency band
starts working.
Mid Ratio (Middle Ratio) 1:1.0–1:16, 1:INF Sets the ratio at which the output in the middle frequency band is
suppressed when the input level has exceeded the middle threshold level.
Mid Atck (Middle Attack) 0–100 ms Sets the time until when the middle frequency band compressor starts
working after the input level has exceeded the middle threshold level.
Mid Rel (Middle Release) 50 ms–5.000 s Sets the time until when the middle frequency band compressor stops
working after the input level has dropped below the middle threshold level.
High Thre (High Threshold) -24–0 dB
Sets the volume at which the compressor for the High frequency band starts
working.
High Raito (High Ratio) 1:1.0–1:16, 1:INF Sets the ratio at which the output in the High frequency band is suppressed
when the input level has exceeded the High threshold level.
High Atck (High Attack) 0–100 ms Sets the time until when the High frequency band compressor starts
working after the input level has exceeded the High threshold level.
High Rel (High Release) 50 ms–5.000 s Sets the time until when the High frequency band compressor stops working
after the input level has dropped below the High threshold level.
Mix (Mixer): Adjusts the volume by frequency band.
Low Level (Low Level) -80– +6 dB Sets the volume in the low frequency band after passing through the
expander and compressor.
Mid Level (Middle Level) -80– +6 dB Sets the middle frequency band volume after passing through the expander
and compressor.
High Level (High Level) -80– +6 dB Sets the volume in the High frequency band after passing through the
expander and compressor.
Lmt (Limiter): Prevents distortion by suppressing signals at High levels.
Sw (Switch) On, Off Turns the limiter on or off.
Thresh (Threshold) -24–0 dB Sets the volume at which the limiter starts working.
Attack (Attack) 0–100 ms Sets the time until when the limiter starts working after the input level has
exceeded threshold level.
Release (Release) 50 ms–5.000 s Sets the time until when the limiter stops working after the input level drops
below the threshold level.
Out (Output): Provides settings concerning overall output.
SoftClip (Soft Clip) On, Off Suppresses conspicuous distortion that may occur when the effect of
compressor/limiter has been applied excessively.
Level (Level) -80– +6 dB Sets the overall volume after passing through the limiter.
*1: If Low Type (Lo Type) or High Type (Hi Type) is set to “Shlv (Shlving Type),” the setting for Lo Q or High Q is
invalid.
• With Compressor, the level is automatically adjusted to the optimal with the settings for Threshold (Thres) and Raito
(Ratio). Setting Attack (Atck) to a relatively long time may cause distortion. For this reason, a margin of -6 dB is
provided. Adjust the Mixer (Mix) level as required.
• “Mastering Tool Kit” cannot be used on EFFECT2 and 4 (even-numbered effects).
• When “Mastering Tool Kit” is used on EFFECT1 and 3 (odd-numbered effects), EFFECT2 and 4 (even-numbered
effects) cannot be used.
• “Mastering Tool Kit” cannot be used on the projects with 64kHz or higher sampling rate.
2400_app_e.book 99 ページ 2005年4月28日 木曜日 午後1時14分