Schneider Electric 58 TRX Computer Drive User Manual


 
Class 8839 Econoflex™ AC Drives
Drive Selection
186
09/2003
© 2000–2003 Schneider Electric All Rights Reserved
DRIVE SELECTION
Class 8839 Econoflexä enclosed drives are tailored for commercial market specifications for pump and fan applications. To select,
identify the catalog number by Class, Type, and Modification(s) numbers as shown below.
Class Type Number Modifications
8839 58E V
➀➁➂➃➄➅
➇➈
Product
Code Enclosed Drive
58E Econoflex
Horsepower
Code
Rating at 208,
230, 460 Vac
C1 HP
D2 HP
E3 HP
F5 HP
G 7.5 HP
H10 HP
J15 HP
K20 HP
L25 HP
M30 HP
N40 HP
P50 HP
Code
Rating at
460 Vac
Q60 HP
R75 HP
S 100 HP
Enclosure Type
Code
Environment
Rating
A Type 12K
G Type 1
Voltage Rating
Code Voltage
2208 Vac
3230 Vac
4460 Vac
Application Type
Code Torque
V Variable Torque
Device Type
Code Power Circuit
W Without Bypass
Y With Bypass
[1]
Misc. Options
Code Feature
A09 Line Reactor
[2]
B09 Line Contactor
[3]
C09
3 to 15 PSI
Transducer
[4]
D09 Omit Keypad
[12]
E09 Smoke Purge
[5]
G09
22 kAIC UL
Coordinated
Rating
H09
Analog Card,
0 to 20 mA
output
[6]
J09
0 to 10 mA
Auto Speed
Reference
[13]
Light Option
Code Light Cluster
A08
Power ON, AFC Run,
AFC Fault, Auto
[7]
B08
Power ON, AFC Run,
AFC Fault, Bypass
[7,8]
C08
Power ON, AFC Run,
AFC Fault
[7,9]
Control Option
Code Controls
A07 Hand-Off-Auto, Speed Potentiometer
[10]
B07
Hand-Off-Auto, Start-Stop,
Speed Potentiometer
[10]
C07 Start-Stop, Speed Potentiometer
[11]
N07 None
N
otes
1. Includes AFC-Off-Bypass switch and Test-Normal switch.
2. Line reactor (A09) is an option for 1 to 20 hp @ 460 V and 1 to 10 hp @ 208/230 V. Line
reactor (A09) is included with 25 to 100 hp @ 460 V and 15 to 50 hp @ 208/230 V.
3. Line contactor (B09) is not compatible with Power Circuit W (Without Bypass).
4. 3 to 15 PSI Transducer (C09) is not compatible with control option C07 (Start-Stop, Speed
Potentiometer), H09 (Analog Card), or J09 (0 to 10 V Auto Speed Reference).
5. Smoke purge E09 permits the motor to run at full speed.
6. Analog card H09 is not compatible with 3 to 15 PSI Transducer (C09).
7. Light Cluster A08, B08, and C08 cannot be selected together; select only one.
8. Light Cluster B08 is not compatible with Power Circuit W (Without Bypass).
9. Light Cluster C08 is not compatible with control option A07 (Hand-Off-Auto, Speed
Potentiometer) or control option B07 (Hand-Off-Auto, Start-Stop, Speed Potentiometer).
10. Hand-Off-Auto switch with Off position for AFC fault reset.
11. Control option C07 (Start-Stop, Speed Potentiometer) is not compatible with Power Circuit
Y (Bypass) or light cluster A08 or B08.
12. Omit the Keypad D09, user must buy a keypad as a separate device to program the
controller.
13. 0-10 V Auto speed reference J09 is not compatible with 3 to 15 PSI Transducer (C09).