PARAMETERS Menu
52
SR2MAN01 11/2007
FBD mode Functions with parameters in FBD mode:
z Numerical Constant-Type Inputs,
z Clocks,
z Gain,
z Timers: TIMER A/C, TIMER B/H, TIMER Li,
z Counters: PRESET COUNT,
z Fast counter,
z CAM block.
To access the parameters of the FBD blocks, you must know end enter the block
number. This number appears in the programming software on the wiring sheet at
the top right corner of the block.
Only those functions used in the program and with parameters are listed in the
PARAMETERS menu.
Parameter
Modification
Parameter modification procedure:
Parameters in
RUN Mode
It is therefore possible to modify parameters in RUN mode dynamically as long as
they are not locked.
The modifications can be made:
z From the PARAMETERS (see PARAMETERS Menu, p. 51) menu,
z From the MONITORING (see MONITORING Menu, p. 53) (LD) menu: Move the
pointer over the function to be modified using the navigation keys and open the
parameters window from the contextual menu (Shift key).
Step Action
1 Place the cursor over the PARAMETERS menu in the main menu (PARAMETERS
flashing) and confirm by pressing the Menu/OK button.
Result: The parameters window opens to the first parameter.
2 Select the function to modify.
To access the required function, scroll through the function block numbers
(navigation keys and ) until you reach the right one.
3 Select the parameter to modify.
The and keys are used to place the cursor over the parameter to modify.
4
Modify the parameter using the + and - keys ( and ) of the contextual menu.
5 Confirm the modifications by pressing Menu/OK, which will open the confirmation
window.
6 Confirm again twice by pressing Menu/OK to save.
Result: The display returns to the INPUTS-OUTPUTS screen in RUN mode and to
the MAIN menu in STOP mode.