PRI Board
Network Configuration
Trunk Groups
On: When Trunk Groups is enabled, all of the PRI lines on the
same E1/T1 Interface Card will use the same number range
as specified for PRI 1, i.e. you will only need to specify the
number range start and stop for port 1 and leave the fields
for the other ports empty. (Default: On)
It is however necessary to set each individual port to On/Off
in the Interface Configuration section below in this menu. See
the next page.
Off: When set to Off, the Trunk Groups is disabled.
Switch Type - Select between the following PRI protocols:
National ISDN•
AT&T Custom ISDN•
ETSI (Euro ISDN)•
Japan/Taiwan ISDN•
NOTE! All PRI lines on the same E1/T1 Interface Card must
use the same PRI Protocol.
Initial Restart
On: When set to On, the PRI interfaces will be reinitialized
after boot (Default: On).
Off: When set to Off, the PRI interfaces will not be reinitial-
ized after boot.
PRI Board in Slot 1-n (3:3)
Alert
On: If set to On, the system will respond with an alert mes-
sage to all incoming setup messages.
Off: If set to Off, the system will respond with an alert mes-
sage only to the incoming setup message related to the initial
channel (Default: Off).
Save - Press the Save button to save changes.
PRI Board Configuration
Please ensure that Network Type is set to PRI for the
correct ISDN cards in the PRI Network Configuration.
!