D 13373.08
NOVEMBER 2007
MPS
Table of
Contents
TANDBERG MPS
ADMINISTRATOR GUIDE
G.703 Board
PRI Board Configuration
!
Please ensure that Network Type is set to G.703 for
the correct ISDN cards in the PRI Network Configura-
tion.
Network Configuration
Physical Layer
Select E1 (max 30+1 channels) or T1 (max 23+1 channels) to
match your ISDN network.
G.703 Board
Leased Line is a non-dialling protocol. Should be used when:
One codec is connected in a point to point connection1.
Through an ISDN switch supporting G.703 Leased Line 2.
mapping.
NOTE! It may be necessary to specify the call rate explicitly
when dialling a G.703 call id to ensure that the correct call
rate is used.
G.703 Board Interfaces (1:2)
Save - Press the Save button to save changes.
Interface (1 to 8)
The interface number refers to the port number/G.703 inter-
face of the Network Interface Card.
Enable
On: If set to On, the port is enabled for G.703 use.
Off: If set to Off, the port is disabled for G.703 use.
Slot (1 to n)
Select Slot 1 to 6 to configure the G.703 (Leased Line) board.
The picture shows one G.703 board installed in Slot 3.
Indicates ok Indicates an error
95
Introduction
Quick
Setup
Using
the MPS
System
Status
Installation
Gateway
Configuration
MCU
Configuration
Technical
Descriptions
Appendices
Main
System
Configuration