TANDBERG MPS 800 Network Card User Manual


 
D 13373.08
NOVEMBER 2007
MPS
Table of
Contents
TANDBERG MPS
ADMINISTRATOR GUIDE
G.703 Board
PRI Board Configuration
!
Please ensure that Network Type is set to G.703 for
the correct ISDN cards in the PRI Network Configura-
tion.
Network Configuration
Physical Layer
Select E1 (max 30+1 channels) or T1 (max 23+1 channels) to
match your ISDN network.
G.703 Board
Leased Line is a non-dialling protocol. Should be used when:
One codec is connected in a point to point connection1.
Through an ISDN switch supporting G.703 Leased Line 2.
mapping.
NOTE! It may be necessary to specify the call rate explicitly
when dialling a G.703 call id to ensure that the correct call
rate is used.
G.703 Board Interfaces (1:2)
Save - Press the Save button to save changes.
Interface (1 to 8)
The interface number refers to the port number/G.703 inter-
face of the Network Interface Card.
Enable
On: If set to On, the port is enabled for G.703 use.
Off: If set to Off, the port is disabled for G.703 use.
Slot (1 to n)
Select Slot 1 to 6 to configure the G.703 (Leased Line) board.
The picture shows one G.703 board installed in Slot 3.
Indicates ok Indicates an error