3.25.1 Function Description
This function logs error information generated while a test is in progress and stores the results in
RAM. This function can store data on a floppy disk or output the data to a printer. If the power
switch is turned off, the error information will be lost. The error information is displayed in the
following order:
1. Error count (CNT)
2. Test name, Subtest number (TS-No)
3. Pass count (PASS)
4. Error status (STS)
5. FDD, HDD or memory address (ADDR)
6. Write data (WD)
7. Read data (RD)
8. HDC status (HSTS)
9. Error status name (ERROR STATUS NAME)
TECRA M2 Maintenance Manual (960-468) 3-67