3 Tests and Diagnostics 3.25 Log Utilities
3.25.2 Operations
Selecting 5 and pressing Enter in the DIAGNOSTIC MENU, logs error information into RAM
or onto a floppy disk. The error information is displayed in the following format:
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
XXXXX ERRORS
CNT TS-No PASS STS ADDR WD RD HSTS [ERROR STATUS NAME]
001 EXP01 0000 XXX 00000000 00 00 0000 FDD-WRITE PROTECTED
001 EXP03 0000 XXX 00000000 00 00 0000 FDD-TIME OUT ERROR
Error status name
Error count
Pass count
Error status
Subtest number
Address
Test name
Read data
Write data
HDC status
1. The error information displayed on the screen can be manipulated by the following
number keys:
1 scrolls the display to the next page.
2 scrolls the display to the previous page.
3 returns to the Diagnostic Menu.
4 erases all error log information in RAM.
5 outputs the error log information to a printer.
6 reads the log information from a floppy disk.
7 writes the log information to a floppy disk.
2. In the case of “error retry OK”, a capital “R” will be placed at the beginning of the error
status. However, it is not added to the error count.
3-68 TECRA M2 Maintenance Manual (960-468)