4 Replacement Procedure 4.27 Fluorescent Lamp
5. Turn the bezel face down, and remove the two screws (E) fixing the lamp cover (F)
and remove the lamp cover. Then replace the lamp unit (G) with a new one.
(E)
(F) Lamp cover
Screw tightening torque:
0.1078N
•
m
(
1.1k
g
f•cm
)
(E)
(G) Lamp unit
Figure 4-75 Replacing Sharp fluorescent lamp (SXGA+) (5)
4-102 TECRA M2 Maintenance Manual (960-468)