Western Telematic AFS-16-1 Switch User Manual


 
15-3
Saving and Restoring Configuration Parameters
15.3. Restoring Previously Saved Parameters
If you make a mistake while configuring the AFS-16 unit, and wish to return to the
previously saved parameters, the Text Interface's "Reboot System" command (/I) offers
the option to reinitialize the AFS-16 using previously backed up parameters. This allows
you to reset the unit to previously saved parameters, even after you have changed
parameters and saved them.
Notes:
• TheAFS-16willautomaticallybackupsavedparametersonceaday,shortly
afterMidnight.Thisconfigurationbackupfilewillcontainonlythemost
recentlysavedAFS-16parameters,andwillbeoverwrittenbythenextnight's
dailybackup.
• Whenthe/Icommandisinvoked,asubmenuwillbedisplayedwhichoffers
severalRebootoptions.Option4isusedtorestoretheconfigurationbackup
file.Thedateshownnexttooption4indicatesthedatethatyoulastchanged
andsavedunitparameters.
• Ifthedailyautomaticconfigurationbackuphasbeentriggeredsincethe
configurationerrorwasmade,andthepreviouslysavedconfigurationhas
beenoverwrittenbynewer,incorrectparameters,thenthisfunctionwillnot
beabletorestorethepreviouslysaved(correct)parameters.
To restore the previously saved configuration, proceed as follows:
1. Access command move via the Text Interface, using a username/password that
permits access to Administrator level commands (see Section 5.1.1.)
2. At the RSM command prompt, type /I and press [Enter]. The AFS-16 will display
a submenu that offers several different reboot options.
3. At the submenu, select Item 4 (Reboot & Restore Last Known Working
Configuration,) type 4, and then press [Enter].
4. The AFS-16 will reboot and previously saved parameters will be restored.