Alarm Configuration
7.6.1. Monitor Input Level Settings
When the Monitor/Alarm Input feature is properly configured, the AFS-16 can trigger an
alarm and/or perform A/B switching operations when the signal at Pin 4 (Monitor Input)
on the Control Module AUX connector goes high or low. In set up this feature, you must
first use the Control Card Jumper to select the non-active (non-alarm) state, and then
use the Monitor/Alarm Input configuration menu to select the active/alarm state (the
signal level that will trigger an alarm) as described in the Sections that follow.
Notes:
• TheMonitorInputsignal(Pin4)isalwaysmeasuredrelativetothesignalat
thecommonground(Pin5).
• A"Low"signalshouldbebetweenZero(0)Voltsand-48Voltsanda"High"
signalshouldbebetween+5Voltsand+48Volts.
1 0
High
Low
Figure7.2:ControlModuleJumper
1 0
Control Card
Jumper
Back Edge of
Control Card
AUX Connector
Pin Out
Pin Signal
5 Ground
4 Monitor Input
Figure7.3:ControlModuleAUXConnector-MonitorInputandGround