Avaya X330WAN Network Router User Manual


 
Controller CLI Commands (X330WAN-2DS1 Only)
Avaya X330WAN User’s Guide 125
remote (Controller context)
Use the remote command to reset the far-end counters.
Note:
1. This command can only be performed if the controller is set to T1.
2. This command is used only when the fdl at&t option is defined.
Syntax
remote <fdl-request-type>
Parameters
Example
X330WAN-2DS1-1(super)# remote Reset-errored-ESF-data
show controllers
Use the show controllers command to display the status of the controller.
Syntax
show controllers [<port>]
Parameters
Output Example for E1
X330WAN-2DS1-1(configure)# show controllers
E1 1 is up.
No alarms detected.
Framing is CRC4, Line Code is HDB3, Clock Source is
Line.
channel-group 1 timeslots 1-31
Data in current interval (778 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0
Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err
Secs, 0 Unavail Secs
fdl-request-type Reset Performance Monitoring Counters | Reset
Errored ESF Data
port
The port number.